Three-phase dry type distribution transformer

Three-phase dry type distribution transformer

Short Description:

The no-load loss of the amorphous alloy dry-type transformer is 75% lower than that of Group 1 in Table 4 of GB/T10228, and the load loss is 15% lower than that of Table 4 of GB/T10228. It is the most advanced energy-saving dry-type transformer in the world.

    Overview details 

    The no-load loss of the amorphous alloy dry-type transformer is 75% lower than that of Group 1 in Table 4 of GB/T10228, and the load loss is 15% lower than that of Table 4 of GB/T10228. It is the most advanced energy-saving dry-type transformer in the world.
    This product has the advantages of low no-load loss, oil-free, flame-retardant and self-extinguishing, moisture-resistant, crack-resistant and maintenance-free. Any place where ordinary dry transformers are currently used can be replaced by amorphous dry transformers, which can be used in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises and power plants. It is especially suitable for installation and use in places with high fire protection requirements such as flammable and explosive.

    Technical parameter

    Rated capacity (kVA)

    Voltage combination and tap range

    association group label

    No-load loss (W)

    Load loss 75℃(W)

    No-load current(%)

    Short circuit impedance(%)

    High voltage (kV)

    High voltage tap range (%)

    Low voltage (kV)

    100

    6 6.3 6.6 10 10.5 11

    ±2x2.5 ±5

    0.4

    Dyn11 Yyn0

    400

    1370

    1.5

    4

    125

    470

    1620

    1.3

    160

    540

    1870

    1.3

    200

    620

    2220

    1.1

    250

    720

    2420

    1.1

    315

    880

    3050

    1

    400

    980

    3500

    1

    500

    1160

    4290

    1

    630

    1300

    5240

    0.85

    6

    800

    1520

    6110

    0.85

    1000

    1770

    7140

    0.85

    1250

    2090

    8510

    0.85

    1600

    2450

    10290

    0.85

    2000

    3050

    12690

    0.7

    2500

    3600

    15080

    0.7

    1600

    2450

    11370

    0.85

    8

    2000

    3050

    14020

    0.7

    2500

    3600

    16590

    0.7


    Note: On-load voltage regulating series transformers only adjust the following two data: 1. The weight increases by 100kg; 2. The on-load switch is arranged on the side a of the transformer and increases by 650mm or the front b increases by 750mm.

     

    description2

    FAQ

    • 1.What are our main products?

      Primary and secondary equipment prefabrication compartment, photovoltaic booster substation, photovoltaic grid-connected cabinet, parallel cage, PV combiner box, MCCB,MCB,The surge protector,tec.
    • 2. If I go to China, can I visit your factory?

    • 3. Can the product be used in harsh environments?