SG(B)10 H-class insulation dry-type power transformer

SG(B)10 H-class insulation dry-type power transformer

Short Description:

SG10 H-class insulation dry-type power transformer has strong thermal shock resistance, large overload capacity, flame retardancy, high fire resistance, low loss, small partial discharge, low noise, no harmful gas, no environmental pollution, insensitive to humidity and dust, small size, no cracking, and easy maintenance. Therefore, it is most suitable for use in harsh environments with high fire protection requirements, large load fluctuations, and dirty and humid environments. Such as: airports, power plants, metallurgical operations, hospitals, high-rise buildings, shopping centers, densely populated areas, and special environments such as petroleum, chemical, nuclear power plants, and nuclear submarines.

    Overview details 

    SG10 H-class insulation dry-type power transformer has strong thermal shock resistance, large overload capacity, flame retardancy, high fire resistance, low loss, small partial discharge, low noise, no harmful gas, no environmental pollution, insensitive to humidity and dust, small size, no cracking, and easy maintenance. Therefore, it is most suitable for use in harsh environments with high fire protection requirements, large load fluctuations, and dirty and humid environments. Such as: airports, power plants, metallurgical operations, hospitals, high-rise buildings, shopping centers, densely populated areas, and special environments such as petroleum, chemical, nuclear power plants, and nuclear submarines.

    Technical parameter

    Rated capacity (kVA)

    Voltage combination and tap range

    association group label

    No-load loss (W)

    Load loss 75℃(W)

    No-load current(%)

    Short circuit impedance(%)

    High voltage (kV)

    High voltage tap range (%)

    Low voltage (kV)

    100

    6 6.3 6.6 10 10.5 11

    ±2x2.5 ±5

    0.4

    Dyn11 Yyn0

    400

    1370

    1.5

    4

    125

    470

    1620

    1.3

    160

    540

    1870

    1.3

    200

    620

    2220

    1.1

    250

    720

    2420

    1.1

    315

    880

    3050

    1

    400

    980

    3500

    1

    500

    1160

    4290

    1

    630

    1300

    5240

    0.85

    6

    800

    1520

    6110

    0.85

    1000

    1770

    7140

    0.85

    1250

    2090

    8510

    0.85

    1600

    2450

    10290

    0.85

    2000

    3050

    12690

    0.7

    2500

    3600

    15080

    0.7

    1600

    2450

    11370

    0.85

    8

    2000

    3050

    14020

    0.7

    2500

    3600

    16590

    0.7


    Note: On-load voltage regulating series transformers only adjust the following two data: 1. The weight increases by 100kg; 2. The on-load switch is arranged on the side a of the transformer and increases by 650mm or the front b increases by 750mm.

     

    description2

    Performance Specifications


    Product standards: GB/T 10228-2015, GB 1094.11-2007

    Rated high voltage: 10(11, 10.5, 6.6, 6.3, 6)kV

    Rated low voltage: 0.4kV

    Connection group: Dyn11 or Yyn0

    High voltage tapping range: ±5% or ±2x2.5%

    Insulation level: LI75AC35/LI0AC5

    Frequency: 50Hz