Welcome to Changsong Electric website!

Leave Your Message
SCB-RL-(30-2500)10 Dry-type distribution transformer

SCB-RL-(30-2500)10 Dry-type distribution transformer

Short Description:

The high and low voltage coils of SCB10 series epoxy resin cast dry-type distribution transformers are cast with thin layers of epoxy resin, which have good insulation performance, strong short-circuit resistance, and high lightning impact resistance. The epoxy resin used for casting has good performance, reasonable design, advanced technology, small partial discharge, low noise, flame retardant, self-extinguishing, moisture-proof, good heat dissipation, maintenance-free, and pollution-free. The product is small in size and low in noise. Each winding has automatic temperature monitoring and protection during operation.

Application scenario:

    Overview details 

    The high and low voltage coils of SCB10 series epoxy resin cast dry-type distribution transformers are cast with thin layers of epoxy resin, which have good insulation performance, strong short-circuit resistance, and high lightning impact resistance. The epoxy resin used for casting has good performance, reasonable design, advanced technology, small partial discharge, low noise, flame retardant, self-extinguishing, moisture-proof, good heat dissipation, maintenance-free, and pollution-free. The product is small in size and low in noise. Each winding has automatic temperature monitoring and protection during operation.
    The surface of the iron core and clamps of SCB10-2500KVA dry-type transformer is specially treated with protective resin, and the appearance is beautiful. The low voltage winding and high voltage winding adopt a segmented multi-layer cylindrical structure, which makes the ampere-turn distribution balanced, the leakage magnetic field small, the mechanical strength high, and the short-circuit resistance strong. The low-noise cooling fan and intelligent temperature controller configured make the product have fault, over-temperature alarm, start-stop protection, and can implement microcomputer remote monitoring function.

    Technical parameter

    Rated capacity (kVA)

    Voltage combination and tap range

    association group label

    No-load loss (W)

    Load loss 75℃(W)

    No-load current(%)

    Short circuit impedance(%)

    High voltage (kV)

    High voltage tap range (%)

    Low voltage (kV)

    100

    6 6.3 6.6 10 10.5 11

    ±2x2.5 ±5

    0.4

    Dyn11 Yyn0

    400

    1370

    1.5

    4

    125

    470

    1620

    1.3

    160

    540

    1870

    1.3

    200

    620

    2220

    1.1

    250

    720

    2420

    1.1

    315

    880

    3050

    1

    400

    980

    3500

    1

    500

    1160

    4290

    1

    630

    1300

    5240

    0.85

    6

    800

    1520

    6110

    0.85

    1000

    1770

    7140

    0.85

    1250

    2090

    8510

    0.85

    1600

    2450

    10290

    0.85

    2000

    3050

    12690

    0.7

    2500

    3600

    15080

    0.7

    1600

    2450

    11370

    0.85

    8

    2000

    3050

    14020

    0.7

    2500

    3600

    16590

    0.7


    Note: On-load voltage regulating series transformers only adjust the following two data: 1. The weight increases by 100kg; 2. The on-load switch is arranged on the side a of the transformer and increases by 650mm or the front b increases by 750mm.

     

    description2

    FAQ

    • 1.What are our main products?

      Primary and secondary equipment prefabrication compartment, photovoltaic booster substation, photovoltaic grid-connected cabinet, parallel cage, PV combiner box, MCCB,MCB,The surge protector,tec.
    • 2. If I go to China, can I visit your factory?

    • 3. Can the product be used in harsh environments?