The internal structure of the photovoltaic grid-connected cabinet mainly consists of the following parts: Indicator light and anti-islanding device: Positioned at the top, they are used to display the grid status and provide protection against islanding. Metering room: Contains electricity meters and other metering equipment to measure and record the power generation and consumption of the photovoltaic system. Equipment in the metering room: Including electroplating meters and multiple control meters, which are used for electric energy metering and control of the system. Circuit breaker and current transformer: Distributed in different positions within the cabinet, they are used for circuit protection and current monitoring. Four-stage knife switch: Used to disconnect the circuit, including the neutral line, when necessary. Inverters and power delivery equipment: Located at the bottom, they convert direct current to alternating current and send the power back to the grid. These components work in unison to ensure the safe and stable operation of the photovoltaic system and optimize the utilization and distribution of electrical energy.‌

  • Switch brand (optional) : Changsong, Delixi, Chint, Changshu, ABB, Schneider
  • Temperature and humidity Operating temperature: -25 to 60℃ Storage temperature: -40 to 70℃ Humidity: 0-90% No frost no corrosive gas place (if there is, please specify)
  • Cabinet material: Cold rolled plate spray, stainless steel
  • Cabinet size (D * W * H) : 600mm*800mm*2200mm/800mm*800mm*2200m (customizable)

Overview details

CSGGD, CSJXF for large-scale photovoltaic grid-connected power generation systems.In order toreduce the connection line and power loss between the inverter and the grid-connected cabinet, it isconvenient to maintain and improve reliability, Generally, an AC combiner box is added between theinverter and the grid-connected cabinet, and the current is configured according to the power oftheinverter. In order to meet this requirement, Im is specially designed to be combined with photovoltaicinverter products to form a complete photovoltaic power generation system solution. The use oftheconfluence AC box allows the user to customize the current and voltage according to the AC and gridrated input current.This product is mainly used in the grid-connected line ofdistributedphotovoltaic system 100Kw-1Mw.

未标题-1       

Conditions For Use

 

Ambient air temperature shall be neither above+40°C nor below-50°CIndoor installation and use,the altitude ofthe use venue shall not exceed 2000MEnvironment relative humidity shall not exceed 50% at the maximum temperature of40°C,highrelative humidity is allowed when the temperature is comparatively low.(for example,it can be90%at +20°C).Also,the impact brought about by occasional condensation due to temperature changeshall be taken into consideration.
The gradient to vertical plane shall not be more than 5 degrees when equipments installation.Equipments shall be installed at places free from excessive vibration and impaction,and where noerosion shall be caused to the electric appliance components.
IF users have any special requirement,please negotiate with the manufacturer for settlement..

 

Technieal Sepcifcation

 

Model

Rated voltage
(V)

Ratedcurrent
(A)

Rated short-circuit
breaking current
(KA)

  Rated short-time
withstand current
      (IS)(KA)

     Rated peak
withstand current
        (KA)

CSGGD1

380

A

  1000

15

15

30

B

  600(630)

C

  400

CSGGD2

380

A

  1500(1600)

30

30

63

B

  1000

C

 

CSGGD3

380

A

  3150

50

50

105

B

  2500

C

  2000

 

 

Execution standard:GB 7251.12-2013/EC61439-2:2011 <low-voltage switchgear and controlgear

assemblies-part 2: Power switchgear and controlgear assemblies>

 

Technical parameter

 

Product model

CSGGD

Number of inverter inputs

1road-5road(It is recommended that an AC bus box be used)

Number of grid-connected output channels

1road

Grid-connection requirement

Three-phase grid-connected cabinet

Grid-connected voltage

AC:380V-AC:500V

Switch brand (optional)

Changsong, Delixi, Chint, Changshu, ABB, Schneider

Protection function

 

Short circuit protection

There are

Overload protection

There are

Lightning protection

There are(Nominal current: In: 20KA, Imax: 40KA, UP≤4kV)

Isolation protection(Visual breakpoint)

There are (knife/disconnecting switch)

Over and under voltage protection

There are

Automatic reclosing

There are

Panel manually open and close

There are

Optional function

1, online power quality monitor; (optional)

2, anti-island protection device; (optional)

3, fault disconnecting device; (optional)

Grid-connected switch

 

Plastic case reclosing (100A-800A) (optional)

1, power grid power failure or bias > 20%, automatic trip (0-10s delay trip time adjustable);

2, the power grid returns to normal, automatic closing;

3, manual operation can be switched to automatic operation;

4, lack of phase protection, break zero protection

5, check the pressure closing

Universal frame Circuit Breaker (200A-4000A) (optional)

1, power grid power failure or bias > 20%, automatic trip (0-10s delay trip time adjustable);

2, the power grid returns to normal, automatic closing;

3, manual operation can be switched to automatic operation

4, lack of phase protection, break zero protection;

5: Check the pressure closing

Environmental applicability

 

Temperature and humidity

Operating temperature: -25 to 60℃ Storage temperature: -40 to 70℃ Humidity: 0-90% No frost no corrosive gas place (if there is, please specify)

Service altitude

≤3000M

Salt spray resistance

Standard salt spray test 336 hours

Conventional parameter

 

Cabinet material

Cold rolled plate spray, stainless steel

Place of use

Indoor type (customizable outdoor type)

Cabinet type

Distribution bin, measuring bin, transformer bin, isolation switch bin

Installation mode

Floor vertical mounting

Cabinet size (D * W * H)

600mm*800mm*2200mm/800mm*800mm*2200m (customizable)