Welcome to Changsong Electric website!

Leave Your Message
Photovoltaic grid connected cabinet PV power generation system

Photovoltaic grid connected cabinet PV power generation system

Short Description:

The photovoltaic grid-connected cabinet is the equipment utilized to convert the direct current energy generated by the photovoltaic power generation system into alternating current energy and inject it into the power system via the connection point. Generally, the photovoltaic grid-connected cabinet is composed of a DC input, an inverter, an AC output, a protection device, and a monitoring system. Through the inverter, it converts the DC power output by the photovoltaic cell pack into the AC power required by the power system, thereby realizing the seamless grid connection between the photovoltaic power generation system and the power system. The photovoltaic grid-connected cabinet achieves efficient energy transmission between the photovoltaic power generation system and the power system mainly through seamless docking with the power system.

  • Switch brand (optional) : Changsong, Delixi, Chint, Changshu, ABB, Schneider
  • Temperature and humidity Operating temperature: -25 to 60℃ Storage temperature: -40 to 70℃ Humidity: 0-90% No frost no corrosive gas place (if there is, please specify)
  • Cabinet material: Cold rolled plate spray, stainless steel
  • Cabinet size (D * W * H) : 600mm*800mm*2200mm/800mm*800mm*2200m (customizable)

Overview details

CSGGD, CSJXF for large-scale photovoltaic grid-connected power generation systems.In order toreduce the connection line and power loss between the inverter and the grid-connected cabinet, it isconvenient to maintain and improve reliability, Generally, an AC combiner box is added between theinverter and the grid-connected cabinet, and the current is configured according to the power oftheinverter. In order to meet this requirement, Im is specially designed to be combined with photovoltaicinverter products to form a complete photovoltaic power generation system solution. The use oftheconfluence AC box allows the user to customize the current and voltage according to the AC and gridrated input current.This product is mainly used in the grid-connected line ofdistributedphotovoltaic system 100Kw-1Mw.

未标题-1       

working principle

1. The output DC power of the photovoltaic cell pack can enter the photovoltaic grid-connected cabinet through the DC input terminal of the cabinet. 

2. The inverter within the photovoltaic grid-connected cabinet converts direct current energy into alternating current power and synchronizes the frequency and phase with the power system.
3. The inverter injects the generated AC power into the power system through the AC output terminal, thus establishing a power transmission channel between the photovoltaic power generation system and the power system. 
4. The background monitoring and control system of the photovoltaic power station monitors and manages the operating status of the photovoltaic grid-connected cabinet in real time to ensure the safe and stable operation of the photovoltaic power generation system.

Conditions For Use

 

Ambient air temperature shall be neither above+40°C nor below-50°CIndoor installation and use,the altitude ofthe use venue shall not exceed 2000MEnvironment relative humidity shall not exceed 50% at the maximum temperature of40°C,highrelative humidity is allowed when the temperature is comparatively low.(for example,it can be90%at +20°C).Also,the impact brought about by occasional condensation due to temperature changeshall be taken into consideration.
The gradient to vertical plane shall not be more than 5 degrees when equipments installation.Equipments shall be installed at places free from excessive vibration and impaction,and where noerosion shall be caused to the electric appliance components.
IF users have any special requirement,please negotiate with the manufacturer for settlement..

 

Technieal Sepcifcation

 

Model

Rated voltage
(V)

Ratedcurrent
(A)

Rated short-circuit
breaking current
(KA)

  Rated short-time
withstand current
      (IS)(KA)

     Rated peak
withstand current
        (KA)

CSGGD1

380

A

  1000

15

15

30

B

  600(630)

C

  400

CSGGD2

380

A

  1500(1600)

30

30

63

B

  1000

C

 

CSGGD3

380

A

  3150

50

50

105

B

  2500

C

  2000

 

Execution standard:GB 7251.12-2013/EC61439-2:2011 <low-voltage switchgear and controlgear

assemblies-part 2: Power switchgear and controlgear assemblies>

 

Technical parameter

 

Product model

CSGGD

Number of inverter inputs

1road-5road(It is recommended that an AC bus box be used)

Number of grid-connected output channels

1road

Grid-connection requirement

Three-phase grid-connected cabinet

Grid-connected voltage

AC:380V-AC:500V

Switch brand (optional)

Changsong, Delixi, Chint, Changshu, ABB, Schneider

Protection function

 

Short circuit protection

There are

Overload protection

There are

Lightning protection

There are(Nominal current: In: 20KA, Imax: 40KA, UP≤4kV)

Isolation protection(Visual breakpoint)

There are (knife/disconnecting switch)

Over and under voltage protection

There are

Automatic reclosing

There are

Panel manually open and close

There are

Optional function

1, online power quality monitor; (optional)

2, anti-island protection device; (optional)

3, fault disconnecting device; (optional)

Grid-connected switch

 

Plastic case reclosing (100A-800A) (optional)

1, power grid power failure or bias > 20%, automatic trip (0-10s delay trip time adjustable);

2, the power grid returns to normal, automatic closing;

3, manual operation can be switched to automatic operation;

4, lack of phase protection, break zero protection

5, check the pressure closing

Universal frame Circuit Breaker (200A-4000A) (optional)

1, power grid power failure or bias > 20%, automatic trip (0-10s delay trip time adjustable);

2, the power grid returns to normal, automatic closing;

3, manual operation can be switched to automatic operation

4, lack of phase protection, break zero protection;

5: Check the pressure closing

Environmental applicability

 

Temperature and humidity

Operating temperature: -25 to 60℃ Storage temperature: -40 to 70℃ Humidity: 0-90% No frost no corrosive gas place (if there is, please specify)

Service altitude

≤3000M

Salt spray resistance

Standard salt spray test 336 hours

Conventional parameter

 

Cabinet material

Cold rolled plate spray, stainless steel

Place of use

Indoor type (customizable outdoor type)

Cabinet type

Distribution bin, measuring bin, transformer bin, isolation switch bin

Installation mode

Floor vertical mounting

Cabinet size (D * W * H)

600mm*800mm*2200mm/800mm*800mm*2200m (customizable)

description2

FAQ

  • 1.What is the installation method?

    Floor vertical mounting
  • 2. Where can I use it?

  • 3. Shell size?