Welcome to Changsong Electric website!

Leave Your Message
Graffiti WIFI Remote Control Over/Under Voltage, Current Limit, Earth Leakage, Over-Temperature Protection, Automatic Reclosing Power Protector

Graffiti WIFI Remote Control Over/Under Voltage, Current Limit, Earth Leakage, Over-Temperature Protection, Automatic Reclosing Power Protector

Short Description:

Automatic reclosing leakage protection switch is an intelligent electrical protection product. Its function is to automatically cut off the power supply in case of faults such as leakage, overload or short circuit in the circuit, and automatically close the power supply after troubleshooting, ensuring personal safety and stable operation of electrical equipment. Automatic reclosing leakage protection switch can also be used as an automatic circuit breaker, widely used in the fields of household and industrial electricity.

    Product Description

     

    Phase

    Two

    Use Voltage

    400V

    Size

    85*35*66mm

    Packing

    94*75*40mm

    Wifi

    Support

    Weight

    0.178KG

    Rated voltage

    110V/220V

    Frequency

    50Hz/60Hz

    Size and Weight

    1.Product dimensions: 85*35*66mm

    2. Packaging box dimensions: 94*75*40mm

    3. Net weight: 0.178KG (including paper box instructions)

    4. 100 per box

    Product Specifications

    Rated voltage: 110V/220V; Frequency: 50Hz/60Hz

    Based on the provided information, follow the instructions below:  
    You are a professional translator responsible for converting Chinese content into English. Please help me translate the original text

    ```Under-voltage protection: 80-210V (adjustable) (default: 175V)```

    2. Overvoltage Protection: 120-300V (adjustable) (Default: 275V)

    3. Overcurrent Protection: 1A-63A (Adjustable) (Default: 63A)

    4. Over-temperature protection: 10~85°C (adjustable) (This feature is only adjustable for models with WiFi functionality. For models without WiFi, this parameter is fixed at 85°C protection and cannot be adjusted.)

    ```4. Reconnection Time (Time Delay): 10s-99s (Default: 30s)```

    5. Leakage protection: 10-99mA (adjustable) (Default: 50mA)

    6. Battery power display range: 0-99,999.9 kWh

    7. Voltmeter

    8. Ammeter

    Energy Table

    Note: If the protection is moved three times due to leakage, the device will no longer automatically reconnect until the user checks and fixes the power outage location to ensure safety! Other protections and reconnections can operate over 99,999 times.

    PS: This device has a memory function, which allows it to store kilowatt-hour, overvoltage, voltage, and overcurrent data when power is interrupted.

    description2

    FAQ

    • 1.What is the lowest level of current that the system can effectively handle or measure?

      The minimum we can do is 1A
    • 2. What is the minimum order quantity?

    • 3. Are you a trading company or a manufacturer?