Welcome to Changsong Electric website!

Leave Your Message
CNCSGK Miniature Circuit Breaker with High - Rated Current Capacity

CNCSGK Miniature Circuit Breaker with High - Rated Current Capacity

Short Description:

The circuit breaker we're exploring here is meticulously designed to cater to the demands of systems requiring a rated current of 125A, showcasing versatility through its 1P, 2P, 3P, and 4P configurations. This flexibility extends its utility across various applications, making it a robust choice for environments where infrequent line switching is the norm. Its broad application spectrum includes not just the backbone of lighting systems but also the intricate distribution networks found within the infrastructure of industrial enterprises, bustling commercial districts, towering high-rise buildings, and cozy residential complexes.



 

 

    MCB Specifications and Standards

    • Miniature circuit breakers with high rated current capacity are important electrical protection devices.

      1. General function

      • They are designed to protect electrical circuits from overcurrent. When the current flowing through the circuit exceeds the rated current capacity of the breaker, it will automatically trip to cut off the circuit, preventing damage to electrical equipment and potential safety hazards such as electrical fires.

      2. Characteristics related to high rated current capacity

      • High - rated current capacity means that they can handle relatively large currents. For example, in some industrial applications or large - power electrical systems in buildings, these miniature circuit breakers can be used to protect circuits with high power consumption. They are able to carry a significant amount of current without tripping under normal operating conditions.
      • Despite their relatively small size (compared to larger circuit breakers used in high - voltage and extremely high - power applications), they are highly efficient in handling high - current situations. This compactness makes them suitable for installation in electrical distribution boards where space may be limited.

      3. Design and construction

      • Inside the miniature circuit breaker, there are precise mechanisms. These include a bimetallic strip which can sense the heat generated by excessive current. When the current is too high, the bimetallic strip bends and triggers the tripping mechanism. Some high - rated current capacity miniature circuit breakers may also incorporate advanced magnetic components to enhance their performance in detecting and responding to overcurrent situations more quickly and accurately.

      4. Applications

      • They are widely used in various electrical systems. In commercial buildings, they can protect the circuits of air - conditioning systems, elevators, and large lighting arrays. In industrial plants, they are used to safeguard the circuits of machinery, motors, and production lines. Additionally, in residential applications, although the power consumption is relatively lower compared to industrial and commercial settings, high - rated current capacity miniature circuit breakers can be used for circuits with high - power appliances such as electric heaters or electric stoves.

      Technical Parameter

      DZ47-125DC Series Circuit Breaker

      DZ47-125DC

      Frame Degree Rated Current (A)

      125A

      Pole

      IP, 2P, 3R 4P

      Rated Operating Voltage (VDC)

      lP250\42P500\43P750\44P1000V

      Rated Current In (A)

      1,2,3,4,6,10,16,20,25,32,40,50,63,80,100,125

      Rated Insulation Voltage Ui (VDC)

      1200VDC

      Rated Impact Voltage Uimp (kV)

      4kV

      Ultimate Breaking Capacity leu (kA)

      4.5kA/6kA

      Run Breaking Capacity les (%lcu)

      75%

      Curve Type

      C

      Trip Type

      Thermal-magnetic

      Mechanical Life

      Actual Average Value

      20000

       

      Standard Value

      8500

      Electric Life

      Actual Average Value

      6000

       

      Standard Value

      2500

      Wiring Capacity (mm2)

      32A, 1~25 mm2J^40A, 10~35mm2

      Ambient Temperature (*C)

      -20-+70

      Altitude

      ^2000

      Relative Humidity

      W95%

      Pollution Level

      3

      Installation Environment

      No obvious shock and vibration

      Installation Category

      Class III

      Installation

      DIN Standard rail

      Dimensions(W)x(H)x(Deep)

      W

      18

      36

      54

      72

       

      H

      80

      80

      80

      80

       

      c

      71

      71

      71

      71

      Weight (kg)

      0.12

      0.24

      0.36

      0.48

      Wiring diagram
      图片1.png图片2.png

      FAQ
      1. Can our company protect the privacy of our customers?
      We are fully committed to honoring our privacy commitments, ensuring that the confidentiality of our clients is safeguarded at all times. This dedication to preserving your rights and interests is at the forefront of our policies, as we understand the importance of trust in our professional relationship.

      2. how can we guarantee quality?
      We ensure that a sample is meticulously examined as a prerequisite to mass production, guaranteeing that all items meet our stringent quality standards. Moreover, a thorough quality check is performed immediately prior to shipping, ensuring that every piece is flawless and ready for customer satisfaction.

    FAQ

    • 1. Is there protection against lightning strikes?

    • 2. Is there anything else besides the basic features?

    • 3.What material is the box made of?