MCB Specifications and Standards
MCB are designed to operate at a nominal voltage of 230/400V AC and a frequency of 50/60Hz. They are rated for a maximum current of 63A and are suitable for use in circuits with a maximum short-circuit capacity of 6000A for 6A-40A rated currents and 4500A for 50A-63A rated currents. MCBs should comply with international standards such as IEC 60898 and national standards such as GB 10963.1.
When selecting an MCB, it is important to consider the following factors:
- Rated current: Choose an MCB with a rated current that matches the expected load of the circuit.
- Tripping characteristics: Different MCBs have different tripping characteristics (e.g., B, C, D types) which are suitable for different types of loads.
- Number of poles: MCBs are available in single-pole, double-pole, three-pole, and four-pole configurations, depending on the application.
MCBs are typically installed in a distribution board or consumer unit, and they should be installed in accordance with the manufacturer's instructions and local electrical codes. It is important to ensure that the MCB is properly wired and that the connections are tight to prevent overheating and arcing.
MCBs are widely used in various applications, including:
- Residential buildings for protection of lighting, socket outlets, and small appliances.
- Commercial buildings for protection of office equipment, vending machines, and HVAC systems.
- Industrial facilities for protection of motors, control panels, and other electrical equipment.
Technical ParameterDZ47-125DC Series Circuit Breaker
DZ47-125DC
Frame Degree Rated Current (A)
125A
Pole
IP, 2P, 3R 4P
Rated Operating Voltage (VDC)
lP250\42P500\43P750\44P1000V
Rated Current In (A)
1,2,3,4,6,10,16,20,25,32,40,50,63,80,100,125
Rated Insulation Voltage Ui (VDC)
1200VDC
Rated Impact Voltage Uimp (kV)
4kV
Ultimate Breaking Capacity leu (kA)
4.5kA/6kA
Run Breaking Capacity les (%lcu)
75%
Curve Type
C
Trip Type
Thermal-magnetic
Mechanical Life
Actual Average Value
20000
Standard Value
8500
Electric Life
Actual Average Value
6000
Standard Value
2500
Wiring diagramWiring Capacity (mm2)
32A, 1~25 mm2J^40A, 10~35mm2
Ambient Temperature (*C)
-20-+70
Altitude
^2000
Relative Humidity
W95%
Pollution Level
3
Installation Environment
No obvious shock and vibration
Installation Category
Class III
Installation
DIN Standard rail
Dimensions(W)x(H)x(Deep)
W
18
36
54
72
H
80
80
80
80
c
71
71
71
71
Weight (kg)
0.12
0.24
0.36
0.48

FAQ
1. What do we produce?
Our core expertise lies in the design and manufacture of a comprehensive suite of photovoltaic electrical solutions, spanning both high and low voltage equipment and components. We are dedicated to advancing the solar energy sector through our innovative and reliable products.
2. Are you a trading company or a factory?
With a legacy of experience behind us, we take pride in our rigorous quality control measures. Each product is subject to rigorous scrutiny, ensuring that only the finest offerings leave our facility, a testament to our dedication to quality and craftsmanship.
FAQ
-
1. Is there protection against lightning strikes?
-
2. Is there anything else besides the basic features?
-
3.What material is the box made of?