Welcome to Changsong Electric website!

Leave Your Message
220kv three-phase oil-immersed on-load voltage regulating transformer Oil Transformer

220kv three-phase oil-immersed on-load voltage regulating transformer Oil Transformer

Short Description:

220kv three-phase oil-immersed on-load tap-changing transformer has brought a series of major changes in materials, technology, structure, etc. It is characterized by compact structure, light weight, high efficiency, low loss, low noise and reliable performance. This product can greatly reduce power grid loss and operating costs, and has significant economic benefits.

Application scenario:

    Overview details 

    220kv three-phase oil-immersed on-load tap-changing transformer has brought a series of major changes in materials, technology, structure, etc. It is characterized by compact structure, light weight, high efficiency, low loss, low noise and reliable performance. This product can greatly reduce power grid loss and operating costs, and has significant economic benefits.
    The products comply with the following national standards: GB1094.1-2013 Power transformers Part 1: General; GB1094.2-2013 Power transformers Part 2. Temperature rise; GB1094.3-2003 Power transformers Part 3: Insulation levels, dielectric tests and external tolerance in air; GB1094.5-2003 Power transformers Part 5: Short-circuit withstand capability; GB/6451-2015 Specifications and technical requirements for three-phase oil-immersed power transformers.

    Technical parameter

     220kv three-phase oil-immersed on-load voltage regulating transformer

    Rated capacity
    (kVA)

    Voltage Group

    Vector set

    No-load loss

    Load loss

    No-load current

    Short circuit impedance

    high pressure
    (kV)

    Low pressure
    k(V)

    kW

    kW

    %

    31500

     

    6.3
    6.6
    10.5
    11

    YNd11

    28

    128

    0.56

    12-14

    40000

     

    32

    149

    0.56

    50000

     

    39

    179

    0.52

    63000

     

    46

    209

    0.52

    75000

     

    10.5
    13.8

    53

    237

    0.48

    90000

     

    64

    273

    0.44

    120000

     

    75

    338

    0.44

    150000

    220±2*2.5%

    10.5,11,13.8

    89

    400

    0.40

    160000

    242±2*2.5%

    15.75

    93

    420

    0.39

    180000

     

    18,20

    102

    459

    0.36

    240000

     

     

    128

    538

    0.33

    300000

     

    13.8
    15.75
    18
    21

    154

    641

    0.30

    360000

     

    17

    735

    0.30

    370000

     

    176

    750

    0.30

    400000

     

    187

    795

    0.28

    420000

     

    193

    824

    0.28


    Note 1: Transformers with rated capacity below 31500kVA and other voltage combinations can also be provided upon request.
    Note 2: 35 kV or 38.5 kV low voltage transformers can also be provided upon request.
    Note 3: A non-split structure is preferred. Sub-connectors may be provided if necessary.
    Note 4: When the annual average load rate of the transformer is between 45% and 50%, the loss value in the table can be used to calculate the maximum operating efficiency.

    description2

    FAQ

    • 1.What are our main products?

      Primary and secondary equipment prefabrication compartment, photovoltaic booster substation, photovoltaic grid-connected cabinet, parallel cage, PV combiner box, MCCB,MCB,The surge protector,tec.
    • 2. If I go to China, can I visit your factory?

    • 3. Can the product be used in harsh environments?